Earth-Rite® MULTIPOINT II

Error: The video (https://youtu.be/TWdaHAjSmkY) couldn't be embedded.
Ficha Técnica

The Earth-Rite® MULTIPOINT II is a unique multi-channel static grounding system that can monitor the simultaneous grounding of up to eight (8) individual pieces of equipment at risk of discharging electrostatic sparks.

To ground and monitor multiple items of equipment at points like multi drum loading stations and mixing stations, tote loading stations and railcar loading racks, a large number of conventional static grounding systems would be required to provide protection against incendive electrostatic sparks. In addition to flammable liquid and gas operations, powder processing equipment that typically includes interconnected pipes, fluid bed dryers, hoppers and micronizers would require multiple grounding systems. With the Earth-Rite® MULTIPOINT II up to eight individual items of potentially isolated equipment can be ground monitored simultaneously with a single static grounding system.

Earth-Rite® MULTIPOINT II applications include:

  • multiple railcar loading points
  • multiple drum / tote loading points
  • powder conveying equipment
  • fluid bed dryers
  • silo / container filling and emptying
  • hoppers and dust collectors
  • powder micronizing, pulverising and grinding equipment

The Earth-Rite MULTIPOINT II multiple static grounding system is ATEX / IECEx / cCSAus certified that identifies when equipment exceeds ground resistance levels outlined in codes of practice including NFPA 77 and IEC 60079-32-1. The system consists of a hazardous area monitoring unit that contains eight pairs of red and green LED indicators that verify when the equipment at risk of static charge accumulation has a resistance of 10 ohms or less to the plant’s designated true earth grounding point.

Benefits

Up to 8 monitored connections

Potentially isolated points as part of one complete circuit.

Attention grabbing LED

Array pinpoints locations that are potentially isolated and at risk of accumulating incendive electrostatic charges.

Corrosion resistant

Hygienic stainless steel.

Marshalling Junction Box

For ease of cable routing and installation.

System Options

Earth-Rite MULTIPOINT II Options

  • Clamps, cables and stainless steel quick connectors for plant and equipment (for temporary or permanent connection).
  • Remote “Hazardous Area” indicator stations.

Certification / Technical

Ingress Protection

IP 66

Power Supply

110/120 V or 220/240 V AC, 50-60 Hz.